Demo data

El Sokhna Plant

Ain Sokhna, Egypt · 4,800 kWp

Generation Today
31,011 kWh
PR 86%
Lifetime Savings
EGP 22,786,058
vs grid baseline
CO₂ Avoided
2,665 t
Level A sustainability
Active Alerts
4

Needs attention

Energy Performance

Generation vs. Consumption (24h)

Energy Flow

Solar Array
Producing 4336 kW
Facility Demand
Using 1328 kW
Public Grid
Exporting 3008 kW

Weather

Irradiance
820 W/m²
Module temp
47°C
Wind
3.2 m/s

Devices

DeviceTypeStatusLast seen
Huawei SUN2000-100K proj-sokhna-inv-1inverterdegraded65 days ago
SMA Sunny Tripower CORE2 proj-sokhna-inv-2inverteroffline65 days ago
Sungrow SG110CX proj-sokhna-inv-3inverteroffline65 days ago
Huawei SUN2000-100K proj-sokhna-inv-4inverteronline65 days ago
SMA Sunny Tripower CORE2 proj-sokhna-inv-5inverteronline65 days ago
Sungrow SG110CX proj-sokhna-inv-6inverteronline65 days ago
Huawei SUN2000-100K proj-sokhna-inv-7inverteronline65 days ago
SMA Sunny Tripower CORE2 proj-sokhna-inv-8inverteronline65 days ago
Sungrow SG110CX proj-sokhna-inv-9inverteronline65 days ago
Huawei SUN2000-100K proj-sokhna-inv-10inverteronline65 days ago
SMA Sunny Tripower CORE2 proj-sokhna-inv-11inverteronline65 days ago
Sungrow SG110CX proj-sokhna-inv-12inverteronline65 days ago
Huawei SUN2000-100K proj-sokhna-inv-13inverteronline65 days ago
SMA Sunny Tripower CORE2 proj-sokhna-inv-14inverteroffline65 days ago
Sungrow SG110CX proj-sokhna-inv-15inverteronline65 days ago
Huawei SUN2000-100K proj-sokhna-inv-16inverteronline65 days ago
SMA Sunny Tripower CORE2 proj-sokhna-inv-17inverteronline65 days ago
Sungrow SG110CX proj-sokhna-inv-18inverteronline65 days ago
Huawei SUN2000-100K proj-sokhna-inv-19inverteronline65 days ago
SMA Sunny Tripower CORE2 proj-sokhna-inv-20inverteronline65 days ago
Sungrow SG110CX proj-sokhna-inv-21inverteronline65 days ago
Huawei SUN2000-100K proj-sokhna-inv-22inverteroffline65 days ago
SMA Sunny Tripower CORE2 proj-sokhna-inv-23inverteronline65 days ago
Sungrow SG110CX proj-sokhna-inv-24inverteroffline65 days ago
Schneider iEM3155 proj-sokhna-meter-1meteronline65 days ago
Kipp & Zonen RT1 proj-sokhna-weather-1weather stationonline65 days ago

Recent alerts

View all
  • GRID-FREQAcknowledged

    Grid frequency deviation observed

    66 days ago

  • WEATHER-DERATEAcknowledged

    Output derated due to high ambient temperature

    66 days ago

  • STRING-IMBALANCE

    String current imbalance detected

    66 days ago

  • WEATHER-DERATE

    Output derated due to high ambient temperature

    66 days ago

  • PR-DROP

    Performance ratio dropped below 0.78

    67 days ago

Monthly Yield

EGP 1,562,216